Option 2: Includes Pump Base with 1" threaded side inlet connection for 1" Floating Filter to connect
Option 3: Includes Pump Base with 1" threaded side inlet connection and required Adapters for 1 1/2" Floating Filter to connect.
Option 4: Includes Pump Base (DOC68) with 1 1/4" threaded side inlet connection and required Adapters for 2" Floating Filter to connect.
DTron3 is a 7” submersible electronic multi-impellers pump for clean water designed for use in wells and tanks. It can be used submerged, partially submerged or on the surface (with the appropriate accessory). It is suitable for use in domestic and residential environments for pressurization, rainwater reuse, gardening and irrigation activities. The pump can be installed even horizontally. Equipped with PLC (PowerLine Communication) technology which allows to communicate with the external controller Com Box supplied as standard. The pump is also available in version X with 1” inlet and kit X which includes 3.2 ft (1 meter) suction hose and float to prevent the suction of impurities from the bottom. The entire pump is classified IP 68, with the DOC68 accessory (supplied separately) it becomes an IP 68 surface pump to be used under the level of the water. On request a certified version for drinking water is available. Integrated expansion vessel, no additional expansion vessel is required.
COM Box: Allows you to change the starting and stopping pressure and to check any alarms triggered by the pump in an easy and intuitive manner (standard for DTron 3).
The BENEFITS of the DTRON3 with Com box over the DTRON2 without a control box.
DTRON2 has a fixed start pressure
DTRON2 45/90 (65.6ft) 29 psi start pressure
DTRON2 35/120 (65.6ft) 22 psi start pressure
DTRON3 adjustable start pressure
DTRON2 45/90 (65.6ft) 29 - 51 psi start pressure
DTRON2 35/120 (65.6ft) 22 - 36 psi start pressure
Too low a CUT-IN value could prevent the pump turning on and keep it off at all times.
Too high a CUT-IN value could cause a DRYRUN alarm.
You can enable and disable the DTRON 3 at the Com box
You can read the pressure in the system on the Com box
You can see the alarm status on the Com box
There is a manual mode on the Com box
You can read alarm status on the Com box
You are going to be able to use to DTRON3’s together in the future
You can use a DConnect2 box with the DTRON3
CONSTRUCTION FEATURES OF THE PUMP Technopolymer pump body to resist corrosion and oxidation. Integrated check valve. Integrated debris filter. Overpressure valve to resist to the formation of ice in the piping and to protect from water hammer. On the pump body there is a air-vent valve that improves priming during the first installation or in the event of emptying the tank/well. Technopolymer handle to move the pump. Integrated 0,04 liter expansion vessel sized to prevent the pump from cycling in the event of small leakages and to compensate in case of water hammer. No maintenance or recharging is required for the integrated vessel. The coupling between the three impellers in technopolymer, the floating ring and the smoothing disc both in stainless steel allow a limited wear of the hydraulics. Suction height can be adjusted using the appropriate accessory (included): 1.4” - 1.6” - 2.4’ or 3.2“ (3.5 - 4 - 6 or 8 cm)
CONSTRUCTION FEATURES OF THE MOTOR Asynchronous submersible water cooling motor. The hydraulic side of the motor shaft is in AISI 303 stainless steel. Double mechanical seal in oil chamber ensuring the pump watertight. Capacitor and integrated anti-overheating motor for thermal protection. Quick coupling/release cable to facilitate installation inside tanks. Anti tear-off power cable connection.
FEATURES OF THE ELECTRONIC The electronic operation allows the pump to start and stop autonomously, by the system requirements and protects against dry run. NFC (Near Field Communication) pocket for the use of a float sensor (supplied separately) connectable without opening the pump. Thanks to PLC communication technology, the pump transmits data throughout the power line. The controller Com Box (included) allows to set the cut-in pressure and to control the alarms. The ANTIBURPING protection protects the pump from false starts in the event of gurgling water. The ANTI-LEAKEAGE protection intervenes in case of leakages in the systems.
TECHNICAL DATA Flow rate maximum: 32.1 gpm (7.3 m3/h) Head up to: 147 ft (45 m) Maximum immersion depth: 49 ft (15 m) Type of pumped liquid: Clean, free from solid or abrasive substances, non-viscous, non-aggressive, non-crystallized and chemically neutral Free passage: 0.08” (2 mm) Minimum suction depth: 4.33” (110 mm) Minimum level of water: 1.38” (35 mm) Liquid temperature range: from 32°F to 122°F (+0°C to +50°C) Minimum and maximum ambient temperature: <32°F to 122°F (+0°C to +50°C) Maximum immersion depth: 15 m Set cut-in: 34.8 psi 2.4 bar (+-0.2) Flanges, thread: Thread 1” 1/4 NPT Pump maximum diameter: 7.28 “ (185 mm) Impeller/s material: Technopolymer/ AISI 304 stainless steel Maximum number of starts: 60/h Non-stop service: yes Protection class: IP 68 Motor insulation class: F Power cable (m) and plug: 49ft (15 m) with plug Single phase power input: 115VV 60 Hz single phase Possible type of installation: Fixed, horizontal or vertical. Submerged or semi-submerged. It can be installed on the surface, under the water level, or outside in a vertical position with the DOC68 accessory (supplied separately). Special versions on request: X version with suction kit for suction at a higher level. Surface version (the DOC68 accessory is required) Certification: CSA, CSAus, NSF 61 and 372 (only model for drinking water
The BENEFITS of the DTRON3 with Com box over the DTRON2 without a control box.
DTRON2 has a fixed start pressure
DTRON2 45/90 (65.6ft) 29 psi start pressure
DTRON2 35/120 (65.6ft) 22 psi start pressure
DTRON3 adjustable start pressure
DTRON2 45/90 (65.6ft) 29 - 51 psi start pressure
DTRON2 35/120 (65.6ft) 22 - 36 psi start pressure
Too low a CUT-IN value could prevent the pump turning on and keep it off at all times.
Too high a CUT-IN value could cause a DRYRUN alarm.
You can enable and disable the DTRON 3 at the Com box
You can read the pressure in the system on the Com box
You can see the alarm status on the Com box
There is a manual mode on the Com box
You can read alarm status on the Com box
You are going to be able to use to DTRON3’s together in the future