NSF 55 includes both Class "A" systems, which require a minimum UV dose of 40mj, for use with waters that are assumed to be contaminated, and Class "B" systems, which require a dose of 16mj. Class "B" systems are only intended to provide supplemental disinfection of non-pathogenic nuisance organisms on water supplies that are otherwise considered potable.

UVMAX E4 (18.5 GPM 120V/230V) is a Class “A” UV system.

Features:

  • Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli and viruses not visible to the naked eye.
  • The special lamp plug ensures that no one can power the UV lamp if it’s not in the UV chamber.
  •  With the push of a button, you can confirm the proper operation of the sensor.
  • Lamps and sleeves are assembled together for ease of handling. They can be replaced separately, in minutes and without tools.
  • The reference card outlines the most important system functions and maintenance for quick, on-the-spot questions.
  •  Indicator lights show the status of system components. Warning lights appear when system maintenance is required.
  •  The lamp timer display starts at 365 and counts down the days to annual lamp replacement. 
  •  Once annual lamp replacement is completed, press this button to restart the lamp timer.
  •  If a warning alarm sounds, simply press this button to silence the alarm.
  •  Our high output validated UV lamp is engineered to treat variable water conditions.

Product: #650682, 650718

Documentation:
Brochure
User Manual

Product Flow Rates

DosageUVRate
30 mJ/cm² 95% UVT @ eoll 18.5 gpm
30 mJ/cm² 95% UVT @ eoll 18.5 gpm
30 mJ/cm² 95% UVT @ eoll 18.5 gpm
30 mJ/cm² 95% UVT @ eoll 18.5 gpm
40 mJ/cm² 95% UVT @ eoll 15.8 gpm
40 mJ/cm² 95% UVT @ eoll 15.8 gpm
40 mJ/cm² 95% UVT @ eoll 15.8 gpm
40 mJ/cm² 95% UVT @ eoll 15.8 gpm

Product Specifications

Dimensions
Length 30 inches
Diameter 4 inches
Power Supply 22 x 15 cm
(8.5" x 6")
Inlet/Outlet Port Size 1" NPT
Shipping Weight 5.9 kg
Reactor Chamber Material 316 SST
Electropolished & Passivated Yes
Electrical
Lamp Type Trojan Low Pressure High Output
Max. current 0.85 Amp
Power Consumption 83 W
Lamp Power 70 W
Voltage 100-250V / 50-60Hz
Operating Parameters
Maximum iron 0.3 ppm
Maximum hardness 120 ppm
(7 grains per gallon)
Maximum humidity 95%
Ambient Temperature 2-40 °C
(36-104 °F)
Maximum Operating Pressure 125 PSI
(8.62 bar)
Minimum Operating Pressure 4 PSI
(27.5 kPa)
Minimum UVT 75 %
Installation Orientation Horizontal or Vertical
Features
UV Intensity Monitor No
Visual "Power On" Yes
Audible Lamp Failure Yes
Audible alarm mute button Yes
Visual Lamp Life Remaining Yes
Lamp Replacement Indicator Yes
Diagnostic Check Yes
Safety Interlock Yes
Flow Restrictor No
COMMcenter control package No
CoolTouch fan No
Colour-coded plug and play connections Yes
Safety cap & special lamp plug Yes
Reference card Yes
Solenoid operation indicator No
Flow Pacing No
Solenoid Valve Optional
4-20 Interface No
Dry Contact Yes
Certifications
CSA Yes
CE Yes
UL Yes